Mean of the relative error E(%) of the reconstructions and its standard deviation with S-SGN and A-SGN approaches, with four and two illuminations and different photon budgets Pb.

  Four illuminations Two illuminations
S-SGN A-SGN S-SGN A-SGN
Pb=103 54.3±10.0 25.9±4.6 57.5±12.3 29.7±6.1
Pb=104 17.9±2.9 8.5±1.1 21.2±4.1 9.8±1.7
Pb=105 7.7±0.7 6.0±0.3 8.7±1.0 6.5±0.3
Pb=106 6.0±0.3 5.8±0.1 6.5±0.3 6.2±0.1
Pb=107 5.78±0.09 5.76±0.03 6.25±0.09 6.21±0.03