Skip to main content
. 2022 Apr 11;54(4):913–916. doi: 10.1016/j.transproceed.2022.03.011

Table 2.

Results of the Function of Transplanted Lungs in Patients With COVID-19

Follow-Up 1* Follow-Up 2
FEV1 (%) 24.26 (11.83-41.15); n = 6 28.74 (11.83-42.93); n = 6
FVC (%) 17.68 (7.71-31.40); n = 7 23.85 (5.27-38.61); n = 5
Distance in 6MWT (m) 116.5 (51.1-256.8); n = 5 306.4 (249.6-363.1); n = 2

The results of spirometry are presented as mean, minimal, and maximal values of significant decreases as a percentage of the baseline value. The results of 6MWT are presented as mean, minimal, and maximal values of significant decreases expressed in meters.

6MWT, 6-minute walk test; FEV1, forced expiratory volume in first second; FVC, forced vital capacity.

*Follow-up 1 was defined as comparing the results before COVID-19 infection and at the first visit after contracting the disease.

Follow-up 2 was defined as comparing the results before COVID-19 infection and at 6 months after contracting the disease.