Skip to main content
. 2022 Apr 11;14:100. doi: 10.1007/s40820-022-00845-1

Table 2.

MXene-based electrochemical aptasensors for cancer diagnosis (sensitivity and detection limit)

S. no. Material Biomarker Sample Technique Linear range LOD References
1 MXenes-BPQDs@Ru(dcbpy)32+-PEIAbCD63 Exosomes, CD63 CV 1.1 × 102 to 1.1 × 107 particles µL−1 37.0 particles µL−1 [166]
2 0D/2D Ti3C2Tx@FePcQD nanohybrid miRNA-155 Serum EIS 0.01 fM to 10 pM 4.3 aM [167]
3 cDNA-Fc/MXene/Apt/Au/GCE aptasensor Mucin 1 Serum SWV 1.0 to 10 µM 0.33 pM [209]
4 MPA-CdS:Eu NC Exosomes, CD63 Serum EIS, ECL 3.4 × 105 to 1.7 × 108 7.41 × 104 particles mL−1 [210]
5 Ti3C2 MXene (MXene) Exosomes, CD63 Cancer cells and Serum CV, EIS 5 × 102 to 5 × 105 particles µL−1 229 particles µL−1 [211]
6 PPy@Ti3C2Tx/PMo12 Osteopontin Serum EIS 0.98 fg mL−1 [212]
7 AuNPs/Ti3C2 MXene miRNA-155 EIS, CV 1.0 fM to 10 nM 0.35 fg [217]
8 MXenes-Apt2/exosomes/Apt1/PNIPAM-AuNPs/GCE Exosomes, CD63 Serum ECL 5.0 × 102 to 5.0 × 106 particles µL−1 125 particles µL−1 [218]
9 MXene-MoS2-Thi-AuNPs/GCE miRNA-21 Serum CV, EIS, SWV 26 fM [219]
10 CoFe2O4@Ag-HB5 cytosensor HER2 positive cells Blood sample CV, EIS 102 to 106 cells mL−1 47 cells mL−1 [220]
11 eCoCu-ZIF@CD-based cytosensor PTK7B16-F10 cells EIS, CV 1.0 × 102 to 1.0 × 105 cells mL−1 33 cells mL−1 [221]