Table 2.

Summary of spectral and Intrabreath oscillometry measurements

Total cohort (n=89) Subgroup with chest CT (n=26)
Absolute values % predicted Absolute values % predicted
R5 (cm H2O s/L) 3.41 (1.26) 114 (36) 3.13 (0.72) 110 (15)
R19 (cm H2O s/L) 2.75 (0.96) 99 (30) 2.63 (0.64) 96.99 (20)
R5–19 (cm H2O s/L) 0.62 (0.63) 245 (409) 0.61 (0.45) 253 (280)
X5 (cm H2O s/L) −2.05 (1.15) 172 (88) −1.85 (1.17) 159 (47)
X5in (cm H2O s/L) −2.10 (1.09) −2.06 (1.18)
X5ex (cm H2O s/L) −1.96 (1.40) −1.61 (1.18)
ΔX5 (cm H2O s/L) −0.25 (0.50) −0.30 (0.37)
AX (cm H2O/L) 12.80 (12.80) 413 (408) 10.30 (11.70) 365 (229)
Fres (Hz) 21.29 (5.0) 167 (48) 20.10 (6.30) 168 (37)
ReE (cm H2O s/L) 2.98 (1.20) 2.64 (0.96)
ReI (cm H2O s/L) 2.17 (0.76) 2.07 (0.53)
ReE-ReI (cm H2O s/L) 0.69 (0.82) 0.50 (0.82)
XeE (cm H2O s/L) −0.24 (0.64) −0.15 (0.60)
XeI (cm H2O s/L) −0.66 (0.74) −0.62 (0.63)
XeE-XeI (cm H2O s/L) 0.38 (0.46) 0.47 (0.51)

Data are shown as median (IQR).

AX, reactance area between 5 Hz and Fres; ex, during expiration phase; Fres, resonance frequency; in, during inspiration phase; R5, resistance at 5 Hz; R19, resistance at 19 Hz, R5–19: R5–R19; ReE, resistance at end-expiration; ReI, resistance at end-inspiration; X5, reactance at 5 Hz; XeE, reactance at end-expiration; XeI, reactance at end-inspiration; ΔX5, difference of X5in and X5ex.