Table 4.
AX | Fres | X5 | X5in | X5ex | XeE | XeI | XeE-XeI | |
TLCCT | 0.387 | 0.216 | 0.387 | 0.356 | 0.389 | 0.303 | 0.536 | 0.095 |
PVV | 0.271 | 0.116 | 0.168 | 0.116 | 0.178 | 0.148 | 0.690 | 0.314 |
ILD extent | 0.230 | 0.135 | 0.141 | 0.133 | 0.156 | 0.119 | 0.615 | 0.265 |
% ground glass | 0.298 | 0.197 | 0.217 | 0.208 | 0.228 | 0.152 | 0.538 | 0.222 |
% reticular | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.504 | 0.215 |
% honeycomb | 0.000 | 0.014 | 0.000 | 0.000 | 0.000 | 0.000 | 0.038 | 0.098 |
Data are shown as the coefficient of determination, and R2 was derived using polynomial with 2 degrees regression. Similar observations (not shown) were made using linear and exponential regression.
ILD extent=sum of %ground glass, %reticular and %honeycomb.
%, per cent predicted; PVV, pulmonary vessel volume; TLCCT, total lung capacity measured by CT.