Skip to main content
. 2022 Mar 23;23(7):3487. doi: 10.3390/ijms23073487

Table 2.

The experimental and predicted activities of 33 training set compounds calculated on the basis of the 3D QSAR-derived Hypo1 model.

BindingDB Code Experimental IC50 nM Predicted IC50 nM Error Experimental Scale Predicted Scale 3D-QSAR Fit Value
BDBM3297 0.1 0.4 4.00 +++ +++ 6.79
BDBM3520 0.3 0.4 1.33 +++ +++ 6.77
BDBM3522 0.4 0.4 1.00 +++ +++ 6.80
BDBM3583 0.4 0.7 1.75 +++ +++ 6.58
BDBM3294 0.8 2.2 2.75 +++ +++ 6.07
BDBM3519 2.0 9.3 4.65 +++ +++ 5.45
BDBM3780 2.7 3.5 1.30 +++ +++ 5.87
BDBM3546 3.8 2.4 −1.58 +++ +++ 6.04
BDBM3535 4.0 2.0 −2.00 +++ +++ 6.12
BDBM3538 4.7 0.4 −11.75 +++ +++ 6.79
BDBM3767 9.4 20.4 2.17 +++ +++ 5.11
BDBM3781 20.0 66.0 3.30 +++ +++ 4.60
BDBM3263 23.0 75.1 3.27 +++ +++ 4.54
BDBM3264 27.0 72.8 2.70 +++ +++ 4.55
BDBM3753 31.0 55.5 1.79 +++ +++ 4.67
BDBM3508 55.0 73.2 1.33 +++ +++ 4.55
BDBM3503 56.0 164.8 2.94 +++ ++ 4.20
BDBM3283 58.0 81.6 1.41 +++ +++ 4.50
BDBM3763 58.0 209.8 3.62 +++ ++ 4.09
BDBM3744 72.0 63.6 −1.13 +++ +++ 4.61
BDBM3265 80.0 72.0 −1.11 +++ +++ 4.56
BDBM3536 84.0 70.5 −1.19 +++ +++ 4.57
BDBM3518 100.0 16.8 −5.95 ++ +++ 5.19
BDBM3516 120.0 79.8 −1.50 ++ +++ 4.51
BDBM3745 132.0 85.6 −1.54 ++ +++ 4.48
BDBM3292 139.0 90.7 −1.53 ++ +++ 4.46
BDBM3757 147.0 57.4 −2.56 ++ +++ 4.66
BDBM3752 264.0 188.8 −1.40 ++ ++ 4.14
BDBM3256 320.0 106.8 −3.00 ++ ++ 4.39
BDBM3259 344.0 202.1 −1.70 ++ ++ 4.11
BDBM3295 348.0 69.2 −5.03 ++ +++ 4.58
BDBM3510 770.0 228.5 −3.37 ++ ++ 4.06
BDBM3269 5500.0 3769.7 −1.46 + + 2.84

Error: The difference between true and estimated activity. A predicted half maximum inhibitory concentration IC50 that is higher than the experimental IC50 is indicated by the “+” sign; in contrast, a predicted IC50 that is lower than the experimental IC50 is indicated by the “−” sign. A value of 1 indicates that the predicted IC50 is equal to the experimental IC50. Activity scale: +++, highly active (IC50 < 100 nM); ++, moderately active (100 nM ≤ IC50 < 1000 nM); +, nominally active or inactive (IC50 ≥ 1000 nM). 3D-QSAR fit value: The fit value indicates the extent to which the features of the 3D QSAR Hypo1 model overlap the chemical features of the training set molecule.