Characteristics of haemodialysis catheters during baseline and intervention phases of trial

Characteristics Baseline phase Intervention phase
Catheters Catheter days Catheters Catheter days
Total No of catheters 5431 497 875 5862 648 390
Insertion on left side of body 1003 (18.5) 82 479 1080 (18.4) 104 582
Vein of insertion:
 Internal jugular 4653 (85.7) 457 083 5130 (87.5) 615 014
 Femoral 592 (10.9) 15 058 554 (9.4) 15 034
 Subclavian 152 (2.8) 21 752 139 (2.4) 13 447
 Other or unknown 34 (0.7) 3982 39 (0.7) 4895
Catheter type*:
 Tunnelled 4069 (74.9) 482 001 4696 (80.1) 633 820
 Non-tunnelled 1361 (25.1) 15 838 1165 (19.9) 14 297
Reason for central venous access:
 Acute kidney injury 1898 (34.9) 95 340 1865 (31.8) 118 947
 Start of maintenance dialysis without functioning access 1808 (33.3) 215 685 2235 (38.1) 302 293
 Transfer from peritoneal dialysis (temporary or permanent) 644 (11.8) 75 709 612 (10.4) 85 541
 Arteriovenous fistula or graft thrombosis 645 (11.9) 70 056 742 (12.7) 89 175
 Arteriovenous fistula or graft infection 95 (1.7) 6636 78 (1.3) 8730
 Other 344 (6.1) 587 331 (5.6) 3514

Values are numbers (percentages) unless stated otherwise. *One catheter in each phase had a missing or unknown type of catheter documented, with corresponding missing catheter day counts of 36 days in baseline phase and 273 in intervention phase.