Table 3.

Summary of voltammetric procedures for painkillers residues determination at the electrochemically pretreated screen-printed electrodes or modified with polymer film in environmental water samples.

Electrode Analyte Method Linear Range [µM] LOD [µM] Application Ref.
aSPCE/SDS DF
PA
TR
DPAdSV 0.001–0.2
0.05–20.0
0.01–0.2
0.2–2.0
0.00021
0.015
river water [82]
electrochemically pretreated SPCE PA
HQ
E2
DPV 0.5–10.0
0.5–10.0
0.5–10.0
0.22
0.19
0.89
tap water [100]
electrochemically pretreated SPGE IB SWV 0.80–30.0 6.30 river water, wastewater [104]
MIP/SPCE DF DPV 0.1–10 0.07 river water,
tap water
[103]

PA–paracetamol; DF–diclofenac; HQ–hydroquinone; E2–estradiol; IB–ibuprofen; DPAdSV–differential-pulse adsorptive stripping voltammetry; DPV–differential-pulse voltammetry; SWV–square-wave voltammetry; aSPCE/SDS–activated screen-printed carbon electrode modified with sodium dodecyl sulfate; electrochemically pretreated SPCE–electrochemically pretreated screen-printed carbon electrode; electrochemically pretreated SPGE–electrochemically pretreated screen-printed graphite electrode; MIP/SPCE–screen-printed carbon electrode modified with molecularly imprinted polymer.