Skip to main content
. 2022 Mar 16;78(Pt 2):195–213. doi: 10.1107/S2052520622001500

Table 8. DCDHQ: user-controlled Rietveld refinements (stage UR).

Models B1 and A3 started from the lowest-energy structures of the DFT-D calculations after re-adjustment of the unit-cell parameters by FIDEL fitted to the experimental pattern. Models C1 and A4 started from the final global optimization results (Table 7). Model A1 started from the best structural model of the automatic Rietveld refinement (see Table S10 in the supporting information) after (re)transformation from P1 to Inline graphic . Model B1Z1 started from B1 after transformation to Inline graphic , Z = 1. The Rietveld refinement of B1Z1 was performed with different settings, hence the R and GoF values cannot be compared with the other refinements. Molecular geometry restraints were derived from DFT-D.

Model Space group Z R exp (%) R wp (%) R wp′ (%) GoF V/Z3 mol−1) a (Å) b (Å) c (Å) α (°) β (°) γ (°)
B1 Inline graphic 2 3.028 5.433 11.448 1.795 389.99 3.852 12.966 16.718 69.89 84.10 88.11
C1 P21/c 2 3.152 9.489 21.314 3.010 421.70 6.508 4.113 31.564 90 93.27 90
A3 Inline graphic 1 3.150 10.816 24.358 3.433 394.71 3.897 6.748 15.656 86.99 89.29 73.77
A4 Inline graphic 1 3.151 10.979 24.568 3.484 380.28 3.752 6.574 15.657 87.17 90.34 80.40
A1 Inline graphic 1 3.150 11.055 25.241 3.509 382.88 3.771 6.578 15.680 92.81 90.89 99.63
B1Z1 Inline graphic 1 3.076 6.322 14.129 2.055 390.27 3.847 6.713 15.673 87.52 91.46 74.99