Skip to main content
. 2022 Apr 1;18(4):e1010030. doi: 10.1371/journal.pcbi.1010030

Table 3. Modifications to model parameters to match the experimental studies setups.

The first row reports the ranges used in our simulation study, while the rows below display the parameters values used to replicate each of the 3 experiments.

Model parameters
Papers SR
[mm]
SD
[mm]
SC
[S/m]
EHTt
[mm]
EHTc
[S/m]
CA
[mm]
CPt
[mm]
CPc
[S/m]
IBT
[mm]
Tissue thickness
[mm]
Range used in this study 0.7–6 0.2–6 0–0.14 0.5–2 0.028–0.224 0.5–2 0.5–2 0–18 0.1–1 1.8–6.6
Jackman et al [21] - - - 1 0.224 0 - - 0.1 3
Thompson et al [17] - - - 0.2 0.224 30 - - 0 0.2
Zimmermann et al [20] 5 3 0 3 0.224 2 - - 0 3
Mawad et al [27] 3 2 0.06 - - - 0.5 16 0 2