Skip to main content
. 2022 Mar 23;13:856219. doi: 10.3389/fneur.2022.856219

Table 2.

Summary of noise exposure for the measured settings and categories.

Setting Sample blocks Noise exposure (dBA)
Mean LAeq (Standard deviation) Cumulative LAeq, Σ
Sound level meter Smartwatch Sound level meter Smartwatch
Bar 12 71.4 (1.1) 72.1 (2.1) 71.5 72.6
Canteen 12 68.7 (4.7) 69.9 (5.2) 70.5 72.0
Cinema 12 72.2 (4.5) 71.5 (4.2) 74.1 73.2
Concert 12 71.7 (7.1) 71.6 (7.7) 76.4 76.8
Construction site 12 83.2 (6.4) 83.8 (7.7) 86.7 90.0
Housekeeping 12 79.0 (6.6) 80.1 (7.6) 82.3 84.1
Museum 12 55.9 (3.1) 52.9 (5.1) 57.1 55.9
Music club 12 95.7 (1.7) 93.9 (1.8) 96.0 94.3
Office 12 49.4 (5.7) 48.6 (7.5) 52.5 52.2
Restaurant 12 77.5 (1.9) 75.7 (2.2) 77.8 76.2
Street 12 69.4 (5.1) 69.5 (5.8) 75.3 77.4
Commuter train 12 63.5 (3.3) 61.3 (4.4) 64.6 63.2
Train station 12 67.0 (1.8) 66.6 (1.6) 67.3 66.9
Category
Occupational settings 72 66.9 (11.0) 66.6 (12.0) 79.4 82.5
Recreational settings 84 74.8 (11.8) 74.0 (12.4) 87.9 86.4
Non-hazardous levels 77 61.9 (7.5) 61.0 (8.4) 65.5 65.3
Tolerable levels 56 75.6 (4.3) 75.1 (3.6) 77.8 76.9
Hazardous levels 23 92.1 (4.8) 90.8 (4.2) 94.1 92.7
Overall 156 71.1 (12.1) 70.6 (12.7) 85.7 85.0