ENVI-met input data for simulations in each case study in Madrid

Simulation days 10th–11th July 2021
Starting time 22:00 h
Simulation period 26 h
Air temperature in 2 m Max 314.26 K at 4:00 PM
Min 292.04 K at 6:00 AM
Relative humidity in 2 m Max 49% at 6:00 AM
Min 12% at 4:00 PM
Wind speed in 10 m 2.00 m-sec
Wind direction 90° (W-E)
Specific Humidity in 2500 m 8.93 g/kg
Solar adjust factor 0.9
Soil temperature Upper layer (0–20 cm) 298 K
Middle layer (20–50 cm) 295 K
Deep layer (50–200 cm) 293 K
Thermal transmittance of walls 0.5 W m−2 K−1 (default value)
Thermal transmittance of roofs 0.5 W m−2 K−1 (default value)
Albedo of walls 0.5 (default value)
Albedo of roofs 0.5 (default value)
Plazas evaluated Number of grids (x, y, z) Size of x grid cells Size of y grid cells Size of z grid cells Number of nesting grids
Plaza de Colón (165,140,30) 2.00 2.00 1.00 2
Plaza Mayor (172,133,30) 2.00 2.00 2.00 2
Plaza de Santa Ana (158,98,17) 2.00 2.00 2.00 2