Skip to main content
. 2022 Apr 11;2022:7194855. doi: 10.1155/2022/7194855

Table 2.

Suppression ability of gas discharge tube to wide and narrow electromagnetic pulses.

Pulse type Narrow pulse (10/100 ns) Wide pulse(10/700 μs)
Number of times Injection voltage peak U1(V) Device response residual voltage peak
U2 (V)
Injection voltage peak U1 (V) Device response residual voltage peak
U2 (V)
1 820 154 520 516
2 1230 508 760 456
3 1490 792 1000 200 (31.6)
4 1880 1000 1600 296 (48.3)

Note: The voltage in brackets is the clamping voltage.