TABLE 2.

Amount of cryogenic coolant required for cold mass cooling [9].

Fluid Helium Hydrogen Nitrogen
Initial metal temperature K 300 77 300 77 300
σ2 Liters σ Liters σ Liters σ Liters σ Liters
per lb per lb per lb per lb per lb
Using latent heat of vaporization only
A1 8.3 30.2 0.4 1.45 0.38 2.42 0.018 0.12 0.83 0.46
SS 4.2 15.1 0.18 0.65 0.2 1.28 0.0085 0.05 0.43 0.24
Cu 3.9 14.1 0.27 0.98 0.17 1.08 0.012 0.08 0.37 0.21
…. and using the enthalpy of the gas
A1 0.2 0.73 0.028 0.1 0.075 0.48 0.0097 0.06 0.51 0.29
SS 0.1 0.36 0.013 0.05 0.037 0.24 0.0045 0.03 0.27 0.15
Cu 0.1 0.36 0.02 0.07 0.037 0.24 0.0065 0.04 0.23 0.13
2

σ = weight of fluid required to cool the same weight of metal to the fluid boiling temperature.