Skip to main content
. 2021 Jun 30;33(4):1023–1030. doi: 10.1007/s00192-021-04897-6

Table 5.

Univariate analysis and multivariate logistic regression final model for failure of the anti-incontinence surgery vs ultrasound parameters

Ultrasound parameters Univariate analysis Multivariate analysis
Odds ratio (95% CI) p value Odds ratio (95% CI) p value
Post-operative open bladder neck 4.75 (1.41–15.99) 0.014 0.60 (0.03–0.07) 0.54
Asymmetry of sling arm 93 (15.27–566.24) <0.0001 4.47 (0.10–0.27) <0.0001
Mesh position
  Proximal 28.63 (3.04–269.13) 0.001 4.71 (0.15–0.38) <0.0001
  Medium 0.04 (0.01–0.14) <0.0001
  Distal 68.20 (11.72–396.70) <0.0001 2.31 (0.01–0.22) 0.02
Concordance of urethral movement with sling on Valsalva
  Concordant 16.00 (2.39–106.73) <0.0001
  Discordant 1.45 (1.04–2.02) <0.0001 12.78 (0.71–0.97) <0.0001
  UVJ moves distal to the sling 2.66 (1.41–5.02) <0.0001 11.76 (0.56–0.79) <0.0001
Bladder neck funneling 20.33 (4.45–92.78) <0.0001 1.74 (0.13–0.009) 0.08

UVJ urethrovesical junction