Skip to main content
. 2022 Apr 21;12(4):e12137. doi: 10.1002/clt2.12137

TABLE 1.

Summary of reduction for all allergens in ambient air by air filtrations (expressed in %)

Home Der f 1 Der p 1 Can f 1 Fel d 1
Home 1 84.9 92.0
Home 2 43.2 94.2
Home 3 91.4 89.7
Home 4 78.6 15.3
Home 5 76.8 91.1 −225.3
Home 6 79.5 89.0 89.5
Home 7 43.6 47.8 93.0
Home 8 98.4 96.1
Home 9 87.0 84.9
Home 10 −30.5 86.3 30.5
Home 11 65.0 31.7 76.6
Home 12 71.9
Home 13 −185.6 68.3
Home 14 79.5 93.9 66.1
Home 15 95.2 77.6
Home 16 56.5 −31.9
Home 17 85.6 95.6 89.7
Home 18 21.1 77.5
Home 19 59.4 71.3
Home 20 88.3 80.6 54.2 −91.8
Home 21 65.7 66.2 89.6 85.8
Home 22 73.5 64.8 45.7
Median (p‐value) 75.2 65.5 89.3 76.6
p < 0.001 p = 0.066 p < 0.01 p < 0.01

Note: Results expressed in median with p‐value included. Negative values represent those homes with non‐effective reduction.