Table 2. Percentage (%) recovery of TiLV from water using iron flocculation method with or without a resuspension step of flocculate-trapped filters soaked in oxalate-EDTA buffer.
Conditions | Number of replications | % Recovery |
---|---|---|
Without resuspension step | 2 | 2.04 ± 0.5 |
With resuspension step | 4 | 16.11 ± 3.3* |
Note:
Representative RT-qPCR results are depicted in Fig. 2D.