Fitting results using model IV for impedance spectra recorded after 48 h exposure in deaerated 0.05 mol dm−3 NaCl solution of titanium samples after anodization at 10 and 30 V at 60 °C for 10 min in DES bath composed of choline dihydrogencitrate salt and oxalic acid.
Sample | R s (Ω cm2) | CPEout-T (Ω−1 cm−2 s−P) | CPEout-P | R out (Ω cm2) | CPEin-T (Ω−1 cm−2 s−P) | CPEin-P | R in (Ω cm2) | Goodness of fit (χ2) |
---|---|---|---|---|---|---|---|---|
Anodized at 10 V | 105 | 2.51 × 10−4 | 0.690 | 1.29 × 103 | 1.23 × 10−5 | 0.929 | 2.77 × 107 | 2.4 × 10−5 |
Anodized at 30 V | 111 | 1.88 × 10−5 | 0.729 | 1.16 × 103 | 7.72 × 10−6 | 0.927 | 8.91 × 1013a | 7.9 × 10−5 |
2 × 107% error for this element.