Skip to main content
. 2021 Jun 14;11(34):21104–21115. doi: 10.1039/d1ra01655e

Fitting results using model IV for impedance spectra recorded after 48 h exposure in deaerated 0.05 mol dm−3 NaCl solution of titanium samples after anodization at 10 and 30 V at 60 °C for 10 min in DES bath composed of choline dihydrogencitrate salt and oxalic acid.

Sample R s (Ω cm2) CPEout-T−1 cm−2 sP) CPEout-P R out (Ω cm2) CPEin-T−1 cm−2 sP) CPEin-P R in (Ω cm2) Goodness of fit (χ2)
Anodized at 10 V 105 2.51 × 10−4 0.690 1.29 × 103 1.23 × 10−5 0.929 2.77 × 107 2.4 × 10−5
Anodized at 30 V 111 1.88 × 10−5 0.729 1.16 × 103 7.72 × 10−6 0.927 8.91 × 1013a 7.9 × 10−5
a

2 × 107% error for this element.