Table 4:
Differences in dark-to-light change in temporal AOD750 and significant determinants between PACD and non-PACD Eyes
| Dark-to-Light Change Mean (STD) |
|||
|---|---|---|---|
| Parameter | No PACD (N = 785) |
PACD (N = 226) |
P-value* |
| AOD750 | 0.111 (0.098) | 0.081 (0.063) | <0.001 |
| ACW | −0.067 (0.133) | 0.004 (0.128) | <0.001 |
| LV | −0.001 (0.088) | 0.028 (0.113) | 0.001 |
| IA | 0.220 (0.113) | 0.215 (0.125) | 0.53 |
| IC | −0.001 (0.128) | −0.013 (0.085) | 0.206 |
| PD | −1.310 (0.508) | −1.280 (0.589) | 0.452 |
Abbreviations: AOD750: Angle opening distance at 750 um from scleral spur. IA: Iris Area. IC: Iris Curvature. IT750: Iris thickness at 750 μm from scleral spur. ACD: Anterior Chamber Depth. LV: Lens Vault. ACW: Anterior Chamber Width. PD: Pupillary Diameter. ACA: Anterior Chamber Area. SRC: Standardized Regression Coefficient. SPCC2: Squared semi-partial correlation coefficient. PACD = Primary Angle Closure Disease. IQR = Interquartile range.