Skip to main content
. 2022 Apr 23;12:6669. doi: 10.1038/s41598-022-10616-y

Table 2.

Corrosion properties of Cu/TiO2 with different TiO2 content in 3.5% NaCl solution.

Nano TiO2 content (wt.%) Electrochemical parameters Impedance measurements
Corrosion current density. (mA/cm2) Corrosion potential Ecorr.(− mV) Ru (ohm) Rp (ohm)
0 0.01 217 35.33 13.99
4 0.026 215 33.57 9.48
8 0.048 165 16.7 6.53
12 0.063 218 13.8 5.2