Skip to main content
. 2021 Jul 16;11(40):24807–24815. doi: 10.1039/d1ra03960a

Calculated activation energy.

α Heating rate, K min−1 Fitting parameters
5 10 15 20 Activation energy E, kJ mol−1 ln(Af(α)) R 2
0.1 T, K 329.3 336.5 350.0 348.3 48.3 5.6 0.9196
dα/dt, s−1 0.5 0.9 1.4 1.7
0.2 T, K 340.9 350.5 363.0 363.0 54.5 7.6 0.9391
dα/dt, s−1 1.0 1.5 2.6 3.6
0.3 T, K 347.6 359.5 370.5 371.7 49.5 5.9 0.9760
dα/dt, s−1 1.4 2.4 3.7 4.6
0.4 T, K 352.6 365.5 376.5 377.7 47.8 5.4 0.9825
dα/dt, s−1 1.8 3.1 4.8 5.8
0.5 T, K 356.8 370.0 381.5 383.0 46.4 4.9 0.9835
dα/dt, s−1 2.2 3.8 5.7 7.0
0.6 T, K 360.5 374.5 385.5 387.7 44.9 4.4 0.9881
dα/dt, s−1 2.6 4.3 6.3 7.7
0.7 T, K 363.4 378.0 389.5 391.7 42.9 3.7 0.9900
dα/dt, s−1 2.7 4.5 6.5 7.8
0.8 T, K 366.8 382.0 393.5 396.3 39.0 2.2 0.9922
dα/dt, s−1 2.6 4.2 5.8 7.0
0.9 T, K 370.9 386.5 398.5 402.3 37.4 1.1 0.9869
dα/dt, s−1 1.7 3.0 3.8 4.4