Table 1.
Author | Publication date | Study goal | Study type | Number of patients | Reconstruction methods | Vendor | Quantitative outcome measures | Abdominal organs | CNR formula |
---|---|---|---|---|---|---|---|---|---|
M. Akagi [12] | Jan 2019 | RS | 46 |
AIDR3D FIRST AiCE |
Canon Medical Systems |
CT value Noise CNR |
Liver | ||
M. Akagi [11] | Oct 2020 | RS | 50 |
AIDR3D FIRST AiCE |
Canon Medical Systems |
Noise CNR |
Liver | ||
L. Cao [13] | Feb 2021 | Using DLR to reduce dose and improve image quality | PS | 40 |
ASIR-V 50% DLR-H |
GE Healthcare |
CT value Noise CNR |
Liver Spleen |
|
Y. Ichikawa [14] | Jan 2021 | RS | 50 |
ASIR-V DLR-H |
GE Healthcare |
Noise SNR/CNR |
Liver | ||
C.T. Jensen [15] | July 2020 | Quantitative and qualitative evaluation of DLR | RS | 40 |
ASIR-V 30% DLR-L/M/H |
GE Healthcare |
CT value Noise CNR |
Liver Spleen |
|
T. Kaga [16] | April 2021 | Evaluating image quality and lesion detection of DLR | PS | 59 |
ASIR-V 40% DLR/L/M/H |
GE Healthcare |
CT value Noise SNR/CNR |
Liver Spleen Pancreas |
|
J.H. Kim [17] | Jan 2021 | Evaluating image quality and DLR | RS | 58 |
ASIR-V 30% DLR-M/H |
GE Healthcare |
CT value Noise SNR/CNR |
Liver | |
L.L. Li [18] | March 2021 | Quantitative and qualitative evaluation of DLR | PS | 47 |
FBP ASIR-V 40/80% DLR-M/H |
GE Healthcare |
CT value Noise SNR/CNR |
Liver Spleen Kidney |
|
Y. Nakamura [19] | July 2019 | RS | 58 |
AIDR3D AiCE |
Canon Medical Systems |
Noise CNR |
Liver | ||
Y. Nakamura [20] | Nov 2020 | RS | 72 |
AIDR3D FIRST AiCE |
Canon Medical Systems |
Noise CNR |
Liver | ||
Y. Noda [21] | Feb 2021 | Evaluating image quality and lesion detection of DLR | PS | 59 |
ASIR-V 40% DLR-H |
GE Healthcare |
CT value SNR |
Liver Spleen Pancreas |
– |
C. Park [22] | Oct 2020 | RS | 37 |
ASIR-V 80//100% DLR-L/M/H |
GE Healthcare |
CT value Noise SNR/CNR |
Liver | ||
R. Singh [23] | Sept 2019 | PS | 59 |
FBP AIDR3D FIRST AiCE |
Canon Medical Systems |
Noise SNR |
Liver | – | |
A. Steuwe [24] | Jan 2021 | RS | 27 |
FBP SAFIRE DLR |
Siemens Healthineers |
CT value Noise SNR/CNR |
Liver Spleen |
||
X. Wang [25] | April 2021 | PS | 251 |
FBP 30% IR DLR 50%/100% |
Neusoft Medical |
Noise SNR/CNR |
Liver | ||
L. Zeng [26] | Feb 2021 | PS | 207 |
HIR 50% DLR |
United Imaging Healthcare |
CT value Noise SNR/CNR |
Liver |
PS prospective, RS retrospective, AIDR3D adaptive iterative dose reduction 3D, FIRST forward-projected model-based iterative reconstruction solution, AiCE advanced intelligent clear-IQ engine, DLR-L/-M/-H deep learning reconstruction low/medium/high, ASIR-V adaptive statistical iterative reconstruction, FBP filtered back-projection, SAFIRE sinogram affirmed iterative reconstruction, IR iterative reconstruction, SNR signal-to-noise ratio, CNR contrast-to-noise ratio