Skip to main content
. 2021 Aug 10;12(3):250–259. doi: 10.1016/j.jtcme.2021.08.003

Table 2.

Parameters measured by working heart perfusion according to Neely.

Control Diabetes Diabetes + 
Stellaria m.
p
Aortic flow (mL) 44.4 ± 2.6 27.3 ± 2.4∗ 34.4 ± 2.3∗ p < 0.05
Coronary flow (mL) 22.8 ± 0.7 21.8 ± 1.5 23.7 ± 1.0 ns
Max dp/dt (mmHg/s) 6323 ± 282 6260 ± 439 6431 ± 487 ns
Min dp/dt (mmHg/s) – 4520 ± 188 – 4512 ± 397 – 4496 ± 374 ns
Aortic diastolic pressure (mmHg) 37.6 ± 0.5 37.9 ± 0.8 37.8 ± 1.1 ns
Aortic systolic pressure (mmHg) 114.8 ± 2.5 110.4 ± 3.3 114.9 ± 3.1 ns
LVDP (mmHg) 136.2 ± 4.6 130.0 ± 4.5 131.3 ± 5.2 ns
Heart rate (1/min) 240 ± 10 211 ± 16 231 ± 11 ns

Results are means ± SEM (n = 8–10), analyzed by one-way ANOVA with Holm-Sidak post hoc test,∗p < 0.05 vs. Control. LVDP left ventricular developed pressure, ns non-significant.