Diagnostic accuracy of cytology, DNA‐ICM and combination tests

Cytology DNA‐ICM Combination
Sensitivity (%) [95% CI] 53.3 [47.7–58.8] 62.3 [56.7–67.5] 75.8 [70.7–80.2]
Specificity (%) [95% CI] 98.3 [95.9–99.4] 91.3 [87.4–94.2] 90.0 [85.9–93.0]
PPV (%) [95% CI] 97.1 [93.1–98.9] 88.6 [83.6–92.3] 89.2 [84.8–92.5]
NPV (%) [95% CI] 66.4 [61.8–70.8] 69.0 [64.2–73.5] 77.4 [72.5–81.6]

Abbreviations: DNA‐ICM, DNA image cytometry; NPV, negative predictive value; PPV, positive predictive value.