Skip to main content
. 2021 Sep 16;11(49):30860–30872. doi: 10.1039/d1ra05519d

The limiting oxygen index and UL-94 vertical burning test of PPUFs and NPUFs.

Sample LOI (%) UL-94
t 1 a (s) t 2 a (s) Dripping Rating
PPUF-0 18.3 BCb Yes NRc
PPUF-10 20.2 19.0 3.7 No V1
PPUF-20 21.6 12.6 3.1 No V0
PPUF-30 23.2 10.5 2.9 No V0
PPUF-40 24.3 8.8 2.5 No V0
PPUF-50 25.2 7.8 2.1 No V0
NPUF-0 18.7 29.3 4.0 Yes V1
NPUF-10 20.8 16.7 3.3 No V1
NPUF-20 21.9 7.5 3.0 No V0
NPUF-30 23.7 5.0 2.7 No V0
NPUF-40 24.6 4.3 2.3 No V0
NPUF-50 25.5 3.4 2.0 No V0
a

t, average combustion times after the flame.

b

BC, burns to clamp.

c

NR, not rated.