Skip to main content
. 2022 Apr 22;15:2127–2135. doi: 10.2147/IDR.S360064

Table 4.

Comparison of the Diagnostic Accuracy Between Xpert MTB/RIF, The CapitalBio Mycobacterium RT-PCR Detection Assay, and Parallel Test for the Diagnosis of Tuberculous Pericarditis Using Pericardial Fluid

Test Sensitivity (P-value) Specificity (P-value) PPV (P-value) NPV (P-value) AUC (P-value)
Xpert vs CapitalBio assay 0.502 1.000 0.796 0.642 0.605
Xpert vs Parallel test 0.480 1.000 0.824 0.585 0.582
CapitalBio assay vs Parallel test 0.171 1.000 0.631 0.316 0.284

Abbreviations: PPV, positive predictive value; NPV, negative predictive value; AUC, area under the curve.