Skip to main content
. 2020 Oct 23;48(13-15):2889–2905. doi: 10.1080/02664763.2020.1837086

Table 3. Suitable orthogonal arrays OA (27, 36).

  FACTORS
Experiment No A B C D E F Cooling Time
(A)
Injection Pressure
(B)
Injection Speed
(C)
Melt Temperature
(D)
Mold Temperature
(E)
Wall Thickness
(F)
1 1 1 1 1 1 1 5 250 5 470 150 2.10
2 1 1 1 1 2 2 5 250 5 470 155 2.15
3 1 1 1 1 3 3 5 250 5 470 160 2.20
4 1 2 2 2 1 1 5 450 10 480 150 2.10
5 1 2 2 2 2 2 5 450 10 480 155 2.15
6 1 2 2 2 3 3 5 450 10 480 160 2.20
7 1 3 3 3 1 1 5 650 15 490 150 2.10
8 1 3 3 3 2 2 5 650 15 490 155 2.15
9 1 3 3 3 3 3 5 650 15 490 160 2.20
10 2 1 2 3 1 2 10 250 10 490 150 2.15
11 2 1 2 3 2 3 10 250 10 490 155 2.20
12 2 1 2 3 3 1 10 250 10 490 160 2.10
13 2 2 3 1 1 2 10 450 15 470 150 2.15
14 2 2 3 1 2 3 10 450 15 470 155 2.20
15 2 2 3 1 3 1 10 450 15 470 160 2.10
16 2 3 1 2 1 2 10 650 5 480 150 2.15
17 2 3 1 2 2 3 10 650 5 480 155 2.20
18 2 3 1 2 3 1 10 650 5 480 160 2.10
19 3 1 3 2 1 3 15 250 15 480 150 2.20
20 3 1 3 2 2 1 15 250 15 480 155 2.10
21 3 1 3 2 3 2 15 250 15 480 160 2.15
22 3 2 1 3 1 3 15 450 5 490 150 2.20
23 3 2 1 3 2 1 15 450 5 490 155 2.10
24 3 2 1 3 3 2 15 450 5 490 160 2.15
25 3 3 2 1 1 3 15 650 10 470 150 2.20
26 3 3 2 1 2 1 15 650 10 470 155 2.10
27 3 3 2 1 3 2 15 650 10 470 160 2.15