Skip to main content
. 2021 Nov 1;11(56):35300–35310. doi: 10.1039/d1ra06660a

Analytical data for silver determined in sulphadiazine and radiological film (n = 6).

Sample Added μg L−1 Founda (μg L−1) Recovery% t-testb F-valueb
Proposed FAAS
Silver sulphadiazine 0.00 7.3 ± 0.3 7.6 ± 0.6
25.0 32.7 ± 0.2 31.9 ± 0.7 101.2 1.26 2.59
50.0 56.9 ± 0.4 58.6 ± 0.9 98.7 1.18 2.56
75.0 81.9 ± 0.5 82.8 ± 0.9 99.1 1.31 2.74
Radiological film 0.00 12.5 ± 0.5 12.7 ± 0.9
75 87.2 ± 0.3 88.8 ± 0.8 99.6 1.67 3.22
150 161.4 ± 0.2 164.8 ± 0.7 99.3 1.43 2.78
225 240.3 ± 0.2 234.5 ± 0.8 101.1 1.69 3.37
Photographic plate 0.00 45.5 ± 0.6 45.3 ± 1.3 1.52 3.03
50 96.2 ± 0.4 93.4 ± 1.1 100.7 1.46 2.95
100 144.1 ± 0.3 147.6 ± 0.8 99.0 1.83 3.87
150 196.9 ± 0.3 192.7 ± 0.9 100.7 1.37 2.98
a

Results average of six consecutive measurements.

b

Theoretical values for t and F at the 95% confidence limit are 2.57 and 5.05, respectively.