Skip to main content
. 2022 Apr 13;9:767906. doi: 10.3389/fcvm.2022.767906

Table 4.

Procedural characteristics and immediate complications of the patients in this study.

Sapien XT (N = 20) Sapien 3 (N = 36) P-value
Vascular access
    Trans-femoral, n (%) 19 (95%) 35 (97%) 1
    Trans-apical, n (%) 1 (5%) 1 (3%) 1
Pre-dilatation, n (%) 20 (100%) 29 (81%) 0.092
Post-dilation, n (%) 7 (35%) 32 (89%) <0.001
Implantation depth from annulus, mm 2.20 ± 1.60 2.36 ± 1.25 0.677
Device success, n (%) 17 (85%) 34 (94%) 0.485
    Paravalvular leakage ≧ moderate, n (%) 2 (10%) 1 (3%) 0.596
    2nd device needed, n (%) 0 (0%) 0 (0%) -
    Post-TAVR trans-valvular PG ≧ 20 mmHg, n (%) 0 (0%) 1 (3%) 1
Procedural success, n (%) 19 (95%) 36 (100%) 0.764
Conversion to SAVR, n (%) 0 (0%) 0 (0%) -
Coronary obstruction, n (%) 2 (10%) 0 (0%) 0.238
Annulus rupture, n (%) 0 (0%) 0 (0%) -
Left ventricular rupture, n (%) 0 (0%) 0 (0%) -
Emergency CPB/ECMO, n (%) 1 (5%) 0 (0%) 0.764
Total procedure time, min 38.70 ± 25.54 31.11 ± 12.14 0.137
Total fluoroscopic time, min 22.93 ± 12.36 19.25 ± 7.15 0.163
Total contrast volume, mL 148.55 ± 56.20 99.97 ± 28.27 0.001

TAVR, transcatheter aortic valve replacement; PG, pressure gradient; SAVR, surgical aortic valve replacement; CPB/ECMO, cardiopulmonary bypass/extracorporeal membrane oxygenation.