Skip to main content
. 2022 Mar 28;14(3):e23568. doi: 10.7759/cureus.23568

Table 5. Miscellaneous structure dosimetry parameters.

3D-CRT - three-dimensional conformal radiotherapy, IMRT - intensity-modulated radiotherapy, VMAT - volumetric-modulated arc therapy

PARAMETER 3D-CRT IMRT VMAT P-value
MEAN SD MEAN SD MEAN SD 3D-CRT- IMRT 3D-CRT-VMAT IMRT-VMAT
MONITOR UNIT 229.44 41.00 793.82 97.10 946.05 139.66 0.000 0.000 0.008
MEAN RIGHT BREAST (GY) 1.19 0.68 2.87   1.19   3.71 0.73 0.000 0.000 0.046
DOSE MEAN (BODY-PTV) [GY] 5.47 0.72   7.41   1.02   7.81 0.83 0.000 0.001 1.000
INTEGRAL DOSE (J) 82.75   19.22   113.68   31.82   119.38   29.49   0.00 0.001 1.000