. 2022 Mar 22;10(2):e02401-21. doi: 10.1128/spectrum.02401-21

TABLE 3.

Analysis of productivity properties of GVPC manufactured without O2 and autoclaved at 115°C, 15 min (conditions 3 vs conditions 1) using real samples from cooling towersa

Type of sample Phaseb CFU/L Legionella spp.
GVPC
Condition 1
GVPC
Condition 3
Water sample n°1 Phase A 0 0
Phase B 100 50
Phase C 0 0
Phase D 50 0
Water sample n°1 + Legionella inoculation Phase A 0 0
Phase B 100 50
Phase C 0 0
Phase D 0 0
Water sample n°2 Phase A 0 0
Phase B 0 50
Phase C 0 0
Phase D 0 0
Water sample n°2 + Legionella inoculation Phase A 0 50
Phase B 200 300
Phase C 50 0
Phase D 50 0
a

Legionella colony count (CFU/L) of water samples from cooling waters.

b

Phase A, direct plating; Phase B, plating of concentrated water from filtration; Phase C, heat treatment (50°C, 30 min); Phase D, acid treatment (HCl-ClK buffer, pH 2.2. for 5 min). The colony reading was performed after 5 incubation days at 37°C.