Test results on the brain tumor MRI dataset.

Method 3D-GLCM (original) 3D-GLCM invariant
Level
Grayscale
Acc Prec Recall Acc Prec Recall
16 60.83 61.22 65.00 90.00 87.67 95.00
32 60.83 61.40 65.00 92.50 87.91 100.00
64 70.00 69.19 70.00 92.50 89.77 96.67
128 81.25 79.32 85.00 96.67 95.39 98.33
256 87.50 87.47 88.33 97.50 97.06 98.33