Skip to main content
. 2020 Jan 29;10(8):4512–4520. doi: 10.1039/c9ra08019h

SESANS fitting parameters calculated using the DAB model.

Solvent PC61BM concentration (mg mL−1) graphic file with name c9ra08019h-t1.jpg Φ PCBM (aggl.) DAB – correlation length [μm] Solubility (mg mL−1)
CHCl3 30 1.8 × 10−3 ± 1.5 × 10−3 0.0016 n/a
60 1.27 × 10−2 ± 2.06 × 10−4 0.012 1.45 ± 0.06 42
90 1.91 × 10−2 ± 1.67 × 10−4 0.023 1.08 ± 0.02 55.5
Toluene 30 (20°) 3.63 × 10−2 ± 5 × 10−4 0.012 1.32 ± 0.04 12
60 (20°) 1.04 × 10−5 ± 1.47 × 10−7 0.037 1.11 ± 0.03 4.5
Chlorobenzene 30 1.02 × 10−3 ± 6.5 × 10−4 0.0006 n/a
60 2.64 × 10−2 ± 2.3 × 10−4 0.016 1.30 ± 0.02 36
90 6.43 × 10−2 ± 6 × 10−4 0.048 1.10 ± 0.01 18
DIO 30 1.16 × 10−3 0.0002 n/a
60 4.89 × 10−2 ± 4.0 × 10−4 0.012 1.14 ± 0.04 42
90 0.13 ± 1.4 × 10−3 0.031 1.23 ± 0.01 43.5