Skip to main content
. 2021 Jul 16;74(8):1442–1449. doi: 10.1093/cid/ciab632

Table 3.

Diagnostic Accuracies of POSITVE, PREDICT, and VIRSTA Scores

Score Sensitivity (% + 95% CI) Specificity (% + 95% CI) Negative Predictive Value (% + 95% CI) Positive Predictive Value (% + 95% CI) AUC
POSITIVEa 77.6 (65.8–86.9) 63.1 (57.3–68.6) 92.5 (87.9–95.8) 32.3 (25.1–40.1) 77.8 (71.9–83.7)
PREDICT day 1 22.9 (14.6–33.5) 97.4 (95.3–98.8) 85.0 (81.4–88.2) 66.7 (47.2–82.7) 71.4 (65.2–77.5)
PREDICT day 5 85.1 (75.8–91.8) 56.9 (51.8–61.9) 94.5 (90.7–97.0) 30.5 (24.7–36.8) 79.7 (73.9–85.4)
VIRSTA 98.9 (95.7–100) 35.7 (30.8–40.6) 99.3 (94.9–100) 25.5 (20.7–30.3) 88.9 (85.3–92.5)

Abbreviations: AUC, area under the receiver operating characteristic curve; CI, confidence interval.

aPOSITIVE score was calculated on the TTP cohort of 362 patients.