Skip to main content
. 2020 Feb 24;10(13):7740–7750. doi: 10.1039/c9ra10539e

Some fluorescent probes previously reported for the detection of H2O2, O2 and 1O2 and their imaging applicationa.

Probes λ ex/λem (nm) Response time (min) Imaging application Ref.
Detection of H 2 O 2
(DCFH-DA) 488/525 20 Eukaryotic culture cell 40
RhH2 507/529 30 Eukaryotic culture cell 41
(DCM-B) 557/688 30 HepG2 cells 42
FE–H2O2 360/540 4 HeLa cells 55
Detection of O 2
DHE 480/610 At least 10 Living cells 43
DPBF UV 420 2 Solution 46
HCy-ONO 765/785 3 Mice 49
HCy-SeH 755/800 30 Mice 56
Detection of 1 O 2
SOSG 504/525 1 Solution 51
ASG 350/537 3 Hela cells 57
MTTA-Eu3+ 294/335 20 Hela cells 58
FN-4 330/378 No data Solution 59
a

DCFH-DA: 2,7-dichlorofluorescin diacetate; RhH2: dihydrorhodamines; DCM-B: (E)-2-(2-(4-((4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)benzyl)oxy)styryl)-4H-chromen-4-ylidene) malononitrile; FE–H2O2: H2O2 reaction site and 4-ferrocenyl(vinyl)pyridine unit; DHE: dihydroethidine; DPBF: 1,3-diphenyl isobenzofuran; SOSG: 2,7-dichlorofluorescin diacetate; ASG: Aarhus Sensor Green; MTTA-Eu3+: [4′-(10-methyl-9-anthryl)-2,2′:6′,2′′-terpyridine-6,6′′-diyl]bis(methylenenitrilo) tetrakis-(acetic acid); FN-4: (E)-2-(2-(furan-2-yl)vinyl) naphtho[1,2-d]oxazole.