Sensor Electrochemical method Analyte Detection limit Linear range Sensitivity Ref.
GQDs-Nafion/GCE DPV Dopamine 0.45 nM 0.005–100 μM 0.0859 μA μM−1 138
GQD/GCE SWV Dopamine 3–100 μM 139
GQD-RuCl3 jCCE Amperometry l-Tyrosine 0.23 μM 1–937 μM 90 nA mM−1 140
Fe3O4 MNPs-GQDs-GCE DPV l-Tyrosine 0.09–230.0 μM 141
rAuNPs/GQDs/GCE SWV Dopamine 3.0 × 10−10 M 1.0 × 10−9 to 1.0 × 10−7 M 0.2245 μA μM−1 142
(GQDs-NHCH2CH2NH)/GCE DPV Dopamine 0.115 μM 1.0–150 μM 1306 μA mM−1 cm−2 143
His-GQD-GMA/GCE DPV Dopamine 2.9 × 10−10 M 1.0 × 10−9 to 8.0 × 10−5 M −0.5482 μA μM−1 144
CS/N,GQDs@SPCE DPV Dopamine 0.145 μM 1.0–200.0 μM 418 μA mM cm−2 145
GCE/GQDs/Lac CV Epinephrine 83 nM 1.0–120.0 × 10−6 M −2.9 mm M−1 cm−2 146
β-CD–GQD/GCE DPV l-Tyrosine 0.1–1.5 μM 863.8 μM mM−1 147
MIP/GQDs/2D-hBN/GCE DPV Serotonin 2.0 × 10−13 M 1.0 × 10−12 to 1.0 × 10−8 M 29.819 μA nM−1 148
GQDs/GCE DPV Dopamine 0.05 μM 0.4–100.0 μM −0.6145 μA μM−1 149
GQD/SPE DPV Dopamine 0.05 μM 0.1–1000.0 μM 0.0745 μA μM−1 150
Tyrosine 0.5 μM 1.0–900.0 μM 0.0495 μA μM−1
GQD-CS/CPE Amperometry Epinephrine 0.3 nM 0.36–380 μM 41 296 μA μM−1 151
GCE/GQDs/AuNPs SWSV Norepinephrine 0.15 μM 0.5–7.5 μM 4.2 × 10−7 μA L μmol−1 152
QD-TMSPED-AuNCs/GC Amperometry Dopamine 5 nM 5 nM to 2.1 μM 0.007 to 0.01 μA nM−1 153
Epinephrine 10 nM 10 nM to 4.0 μM 0.01 μA nM−1
GQDs/IL/CPE DPV Norepinephrine 0.06 μM 0.2–400.0 μM 0.0951 μA μM−1 154