Heat capacity of pure binary carbonates prepared over rates (2, 6, and 10 °C min−1), measured by a differential scanning calorimeter (DSC 25, TA Instruments) at 540 °C. The unit is kJ kg−1 °C−1.

Sample # Test # 2 °C min−1 6 °C min−1 10 °C min−1
1 1 1.53 1.63 1.57
2 1.53 1.63 1.57
3 1.53 1.59 1.57
2 1 1.59 1.57 1.62
2 1.58 1.57 1.60
3 1.58 1.56 1.61
3 1 1.6 1.55 1.60
2 1.6 1.56 1.60
3 1.59 1.56 1.57
Average 1.57 1.58 1.59
Standard deviation 0.03 0.03 0.02