Compression and flexural modulus values ± standard deviation obtained for experimental bone cements. Control (sample without CS), (sheets) sample with 7 wt% of CS sheets, (spheres) sample with 17 wt% of CS spheres.

Sample Compressive strength (MPa) Flexural strength (MPa) Flexural modulus (MPa)
Control 108.68 ± 1.1 50.97 ± 2.1 2422.83 ± 215.9
Sheets 94.08 ± 1.8 34.25 ± 0.76 2113.76 ± 375.5
Spheres 93.32 ± 1.9 26.34 ± 0.72 2068.23 ± 447.1