Skip to main content
. 2022 Mar 31;14(3):e23716. doi: 10.7759/cureus.23716

Table 3. Dosimetric parameters of the OARs in two techniques (mean±SD).

IMRT, intensity-modulated radiation therapy; SD, standard deviation; OAR, organ at risk

  IMRT 1 IMRT 2 p-value
Brainstem 33.40±14.73 35.96±11.24 0.64
Right optic nerve 5.57±5.14 4.86±4.49 0.01
Left optic nerve 4.88±4.12 4.36±3.76 0.11
Right eye 11.64±11.56 7.88±9.11 0.08
Left eye 7.39±8.33 6.19±7.42 0.02
Right lens 5.32±7.24 2.66±1.56 0.28
Left lens 3.13±2.01 2.77±1.86 0
Parotid right 40.19±17.33 41.47±16.97 0.65
Parotid left 44.30±12.38 43.75±12.27 0.74
Left cochlea 19.69±14.57 18.26±13.54 0.04
Right cochlea 22.83±11.11 22.11±11.49 0.44
Lips 26.05±5.01 24.18±7.00 0.11
PRV spine 42.46±4.45 42.25±4.38 0.64
Mandible 67.61±4.97 67.52±5.32 0.8