Skip to main content
. 2022 Apr 13;24(4):241–248. doi: 10.1089/dia.2021.0362

Table 4.

System Setting Ratios (Actual/Calculated) and Percentage Time-in-Range

Variable Mean (SD) Min Max
Basal ratio 1.09 (0.272) 0.58 1.62
ISF ratio 1.25 (0.528) 0.03 2.23
CIR 1.07 (0.325) 0.62 1.73
TIR (%) 75.74 (16.638) 33.83 97.03

n = 22 for discontinuer subsample with system settings data. Ratios compare actual setting divided by calculated (optimal) setting, with values closer to 1 reflecting more congruency between actual and calculated settings.

CIR, carbohydrate-to-insulin ratio; ISF, insulin sensitivity factor; SD, standard deviation.