Skip to main content
. 2020 May 27;10(34):20231–20244. doi: 10.1039/d0ra02979c

Application of pre-ozone oxidation to treat water.

Raw water Coagulant Dose (mg L−1) Observation Reference
Disperse dye-bath FeSO4 2300 Eliminated 95% color and 48% COD 98
Saline landfill leachates Fe2(SO4)3 49 Leachate treatment led to 100% removal of leachate color and 78% removal of COD 99
Textile wastewater Al2(SO4)3, FeSO4 53.7–82.3 Almost complete color absorbance (over 98%) was removed in 20 min ozone contact time 80
Taihu Lake Alum 0.45 THMFP removal by approximately 60% 100
Oilfield-produced water PAC, PAM 5 PAC and PAM could be saved by approximately 10 mg L−1 and 5 mg L−1 101
Waterworks PAC 0.5 Improve THMFP coagulation removal by 14% 73
Municipal wastewater PACl 0.8 DON, DOC, and UV254 removal of 71%, 66%, and 97% 10
Chodatella sp. Alum 0–2.1 Increasing algae removal by approximately 50% 88
Oscillatoria agardii Al2(SO4)3 0–2 Increasing algae removal by 8% 102
Green algae mixture FeCl3 1 Increasing algae removal by approximately 20% 103