Table 6.

The comparative accuracy, sensitivity, specificity, precision, and F1-score results of the proposed OSFP-Net and other well-known classification methods. The p value for the statistical T-test is shown in the brackets.

Methods Accuracy (%) Sensitivity (%) Specificity (%) Precision (%) F1-score (%)
ResNext50 88.4 (1.8E-08) 88.7 (0.026) 88.0 (0.0002) 79.7 (0.0001) 83.9 (0.0002)
DenseNet121 88.2 (2.8E-09) 81.6 (0.001) 91.7 (0.0008) 83.6 (0.002) 82.5 (0.0002)
EfficientNet-b7 86.5 (1.2E-10) 83.0 (0.0009) 88.4 (7.8E-05) 78.7 (0.0007) 80.7 (0.0002)
OSFP-Net 97.3 96.2 97.6 95.8 95.9