Table 6.
The comparative accuracy, sensitivity, specificity, precision, and F1-score results of the proposed OSFP-Net and other well-known classification methods. The p value for the statistical T-test is shown in the brackets.
| Methods | Accuracy (%) | Sensitivity (%) | Specificity (%) | Precision (%) | F1-score (%) |
|---|---|---|---|---|---|
| ResNext50 | 88.4 (1.8E-08) | 88.7 (0.026) | 88.0 (0.0002) | 79.7 (0.0001) | 83.9 (0.0002) |
| DenseNet121 | 88.2 (2.8E-09) | 81.6 (0.001) | 91.7 (0.0008) | 83.6 (0.002) | 82.5 (0.0002) |
| EfficientNet-b7 | 86.5 (1.2E-10) | 83.0 (0.0009) | 88.4 (7.8E-05) | 78.7 (0.0007) | 80.7 (0.0002) |
| OSFP-Net | 97.3 | 96.2 | 97.6 | 95.8 | 95.9 |