Skip to main content
. 2019 Mar 14;9(15):8537–8545. doi: 10.1039/c9ra00106a

Corrosion inhibition efficiency values of epoxy and GO + Nd coated Ti6Al4V alloys and film thickness values.

S. no. Ecorr (mV) Icorr (mA) (%) R ct (Ω cm2) C dl μF χ 2 (Å)
Epoxy 122 6.179 480 3.7046 1.7149 1.0952
GO + Nd 850 2.201 64.5 970 2.7333 0.7670 1.4872