Kinetic parameters determined by fitting the kinetic model to the experimental results.
| Parameter | Pre-exponential factor | Activation energy, kJ mol−1 |
|---|---|---|
| k 1 | 0.7965 ± 0.0747 mol kg−1 s−1 kPa−1 | 73.18 ± 7.77 |
| k 2 | 0.0148 ± 0.0021 mol kg−1 s−1 kPa−1 | 8.89 ± 2.48 |
| k 3 | 0.0019 ± 0.0008 mol kg−1 s−1 kPa−1 | 76.83 ± 24.85 |
| k 4 | 0.0082 ± 0.0011 mol kg−1 s−1 kPa−1 | 37.50 ± 5.88 |
| k 5 | 0.0095 ± 0.0012 mol kg−1 s−1 kPa−1 | 15.45 ± 3.72 |
| k 6 | 0.0028 ± 0.0009 mol kg−1 s−1 kPa−1 | 6.60 ± 10.41 |
| k 7 | 0.0139 ± 0.0038 mol kg−1 s−1 kPa−1 | 23.18 ± 15.74 |
| α | 0.0800 ± 0.0065 kP−1 h−1 | 104.54 ± 7.83 |
| β | 0.0010 ± 0.0005 kP−1 h−1 | 224.86 ± 25.27 |
| m | 0.13 ± 0.05 |