Skip to main content
. 2019 Jul 16;9(38):22106–22115. doi: 10.1039/c9ra03311d

Analytical parameters for the determination of l-ORN.

Parameter Value Parameter Value
Wavelength, λmax (nm) 469 Slope (b) 0.0180
Linear range, (μg mL−1)a 5.00–50.00 Intercept (a) 0.1036
S b 2.41 × 10−4 r 2 0.9991
±tSb 1.67 × 10−4 LOD (μg mL−1)b 1.77
S a 6.90 × 10−3 LOQ (μg mL−1)b 5.38
±tSa 4.78 × 10−3 Residual SS 4.70 × 10−4
S y/x 9.69 × 10−3 Regression SS 0.5257
a

Regression equation: Y = bX + a, where Y is the absorbance, X is concentration in M, a is the intercept, b is the slope, Sb = SD of slope, ±tSb = confidence limit for slope, Sa = SD of intercept ± tSa = confidence limit for intercept Sy/x = SD of the regression, SS is sum of squares.

b

LOD = limit of detection, LOQ = limit of quantification, and r2 = coefficient of determination.