Skip to main content
. 2022 Apr 8;9(Pt 3):342–348. doi: 10.1107/S2052252522003657

Table 1. Data-collection and refinement statistics.

Values in parentheses are for the outer shell.

  X-ray/neutron analysis Neutron analysis X-ray (1.72 Å)/neutron analysis
  PDB entry 6l9c PDB entry 7wno PDB entry 7wnp
  X-ray Neutron Neutron X-ray Neutron
Data collection
 Beamline BL5A, PF BL03, J-PARC   BL5A, PF  
 Wavelength (Å) 1.0 3.0–5.7   1.0  
 Space group C2     C2  
a, b, c (Å) 157.55, 61.78, 92.23     157.21, 61.98, 92.45  
 α, β, γ (°) 90, 112.13, 90     90, 112.13, 90  
 Resolution range (Å) 50.00–1.14 (1.16–1.14) 20.94–1.72 (1.78–1.72)   44.55–1.72 (1.82–1.72)  
R int 0.069 (0.801) 0.188 (0.596)   0.053 (0.240)  
 〈I/σ(I)〉 46.6 (2.00) 4.99 (1.03)   9.27 (2.54)  
 Completeness (%) 99.4 (99.9) 87.4 (66.6)   93.1 (91.3)  
 Multiplicity 5.2 (3.5) 2.66 (1.62)   1.91 (1.90)  
 Observed reflections 1526790 203270   308652  
 Unique reflections 296297 (14901) 76306 (5748)   161381 (25556)  
Refinement
 Resolution range (Å) 45.03–1.14 (1.15–1.14) 20.95–1.72 (1.74–1.72) 20.95–1.72 (1.74–1.72) 32.06–1.72 (1.73–1.72) 21.00–1.72 (1.74–1.72)
R work 0.1678 (0.3071) 0.1865 (0.3215) 0.1632 (0.2639) 0.1569 (0.2475) 0.1912 (0.3194)
R free 0.1821 (0.3207) 0.2146 (0.3428) 0.2568 (0.3386) 0.1894 (0.3100) 0.2348 (0.3595)
 Average B factors (Å2)
  Protein 24.63   20.37 20.06  
  Ligands (TPQ/Cu2+) 23.33   18.21 17.72  
  Waters 39.77   41.08 35.54  
 R.m.s. deviations
  Bond lengths (Å) 0.028   0.006 0.010  
  Bond angles (°) 1.026   1.141 1.265  
 No. of solvent atoms 1063   1115 [719§] 960 [806§]  
 No. of multiple conformers 55   21 4  
 Ramachandran plot (%)
  Favoured regions 96.2   96.7 96.8  
  Allowed regions 3.7   3.1 3.0  
  Outliers 0.1   0.2 0.2  

Data from Murakawa et al. (2020).

The low values of completeness and multiplicity are due to the elimination of some reflection spots with an elliptical shape (presumably derived from a distorted portion of the crystal) in the integration process.

§

Number of water molecules detected at approximately the same location (within 1.0 Å) as those detected by X-ray/neutron analysis.