Skip to main content
. 2019 Jul 23;9(39):22677–22684. doi: 10.1039/c9ra02665g

Comparison of the optimal method with reference methods.

Method Extraction conditions Extraction yield (mg g−1)
Solvent Method Temperature Time
Ref-1 28 mL g−1 73%EtOH Heating 83 °C 4 h 1.54 ± 0.26
Ref-2 28 mL g−1 73%EtOH MAE 68 °C 20 min 1.84 ± 0.04
Ref-3 30 mL g−1 NADES Heating 83 °C 4 h 2.24 ± 0.03
Optimal method 30 mL g−1 NADES MAE 68 °C 20 min 2.32 ± 0.01