Skip to main content
. 2022 Apr 21;10:857638. doi: 10.3389/fbioe.2022.857638

TABLE 1.

Maximum stretches in the in-plane and shear directions during equibiaxial tests. Data are presented as mean ± SEM.

Ventricle λ L λ C k LC (shear) k CL (shear)
LV (n = 7) 1.14±0.02 1.19±0.02 1.04±0.01 a , b 1.02±0.02 a , b
RV (n = 7) 1.20±0.02 1.14±0.01 1.02±0.01 a , b 1.03±0.01 a , b
a

p < 0.001 vs. λ L .

b

p < 0.001 vs. λ C .

λ L , stretch in the longitudinal direction; λ C , stretch in the circumferential direction; k LC and k CL , stretches in the shear directions.