Table 5.
Performance of the designed DNN with different pathologies.
| Pathology | Accuracy | F1 score | Recall | Precision |
|---|---|---|---|---|
| Dysphonia × healthy | 85.71% | 68.12% | 64.50% | 83.07% |
| Cordectomy × healthy | 96.77% | 94.47% | 91.66% | 98.07% |
| Dysody × healthy | 81.25% | 78.18% | 76.92% | 88% |
| Functional dysphonia × healthy | 86.04% | 85.97% | 85.97% | 85.97% |
| Laryngitis × healthy | 93.87% | 93.48% | 93.07% | 93.99% |
| Leukoplakia × healthy | 89.06% | 70.03% | 65% | 94.26% |