Skip to main content
. 2022 Apr 4;2022:7814952. doi: 10.1155/2022/7814952

Table 5.

Performance of the designed DNN with different pathologies.

Pathology Accuracy F1 score Recall Precision
Dysphonia × healthy 85.71% 68.12% 64.50% 83.07%
Cordectomy × healthy 96.77% 94.47% 91.66% 98.07%
Dysody × healthy 81.25% 78.18% 76.92% 88%
Functional dysphonia × healthy 86.04% 85.97% 85.97% 85.97%
Laryngitis × healthy 93.87% 93.48% 93.07% 93.99%
Leukoplakia × healthy 89.06% 70.03% 65% 94.26%