Electrodes Linear range (μmol L−1) LOD (nmol L−1) Ref.
GCE 0.01–1.0 5.0 42
AuNCs/CILE 0.001–1.0 0.4 10
MWCNTsa–PEIb/GCE 0.0024–1.75 0.5 11
GNsc/HAd/GCE 0.2–10.0 10.0 43
HAP–CNTe/GCE 0.4–12.0 80.0 44
PDDA–G–CNTsf/β-CDg/GCE 0.05–60.0 20.0 45
Au–BMIPF6h–CPEi 0.1–5.8 28.0 46
PCVj/MWCNTs/GCE 0.2–10.0 5.0 47
Pt–BPC/CILE 0.008–100.0 2.6 This study
a

Multi-walled carbon nanotubes.

b

Polyethyleneimine.

c

Graphene nanosheets.

d

Hydroxyapatite.

e

Hydroxyapatite–carbon nanotube.

f

Poly (diallyldimethylammonium chloride)–graphene sheets–multiwalled carbon nanotubes.

g

β-Cyclodextrin.

h

1-Butyl-3-methylimidazolium hexafluorophosphate.

i

Carbon paste electrode.

j

Poly (crystal violet).